Chat online
Home > CCC Products Trade > Trade Offers > Electrical Equipment & Supplies > Battery Chargers

MP3 Charger (Xima Digital (Shenzhen) Co., Ltd.,China)

Description

Detailed Product Description

Style: MP3 charger
1) Rated output voltage: DC 5V
2) Output position: USB interface
3) Output current: 200-300mA
4) Max. output power: 1.5W
5) Efficiency (typical): 61%
6) Input voltage range: 100-240V
7) Input frequency range: 47-63Hz
8) Output voltage accuracy: no load voltage: 5.0-6.5V
9) Max. input regulation factor: ±10%
10) Max. load regulation: ±20%
11) Output ripple and yawp: 15% of output voltage (max.)
12) Output overpressure protection: 120-170% (adjustable as customer's request)
13) Output over-current protection: over-current protection point about 110-160%
rated output current; recover point <120%; power supply protection status: online
current-limited voltage drop mode; when connect to power, the indication light
turn red; when connect to MP3 player, the indication light turn green; when battery
charge is full, the green indication turn off
14) Charging status: charging current is the most while there is no power in battery;
charging time the longest. While battery is in full condition, charging time
is shorter or no need charge. When battery is full, the charging current is 10-20mA,
and charging time is 3.5-4h in general conditions
15) High-pressure isolation voltage: input end - output end: AC 1.5kV/50Hz adding
power, 1min: current leak <5mA
16) Working temperature parameter:  working temperature coefficient is ±0.05%/°C;
absolute coefficient is 0.8°C/W; absolute temperature rise is 25°C±5°C
while working output is rated power
17) Environment parameter: storage environment: -20°C~+85°C; 10%~95% RH;
working environment: -20°C~+50°C; 20%~90% RH (depends on using environment
and power)
18) Heating loss mode: consecutive working system, machine body naturally cooling
(using environment and fixing position difference to influence power usage quantity
19) Dimensions: L59 x W25 x H48mm
20) Net weight: total 67g
21) Design criterion: Nation Standard GB-4943-2001; GB17625.1-1998
22) Stability test: complies with MIL-HDBK-217 BELLCORE TR-MWT-332
Note:
1) Inspection index stated above is gotten from under condition: in the area of input
rated voltage and output rated loading. Environment: 25°C, 85% RH, when
there is no wind moving around
2) Output voltage DC ripple test: at the test point, with a parallel twisting string
(30cm long, section: 1m², connect 0.1μF and 0.47μF capacitance
with one side), respectively inspect the largest number Vp-p 100Hz of 100Hz main
frequency and general ripple Vp-p max.
3) Li voltage regulation factor: input voltage changing in rated area while load
is rated; Li regulation factor: load is changing from 0 to rated value
Contact Information
Company Name :
Company Address :
Chat online:
Company Website :    
View 's Detailed Information